  • CLAMP ON POWER HiTESTERÿ ( Hioki 3286-20)

CLAMP ON POWER HiTESTERÿ ( Hioki 3286-20)

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
15 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail CLAMP ON POWER HiTESTERÿ ( Hioki 3286-20)

Functionality and Safety Packed into a Handheld Unit Single phase 600 kW & up to 20th Harmonic levels measurement Active/ reactive/ apparent power, Power factor, Phase detection, Frequency, Harmonic waveform value, or Waveform peak value Simple checking of three-phase lines ( Should be balanced and no distortion) Note: The 3286-20' s three-phase power measurement method calculates and displays the power values for a sine wave input at 50/ 60 Hz, assuming it is balanced and there is no distortion. Accurate measurement is not possible on a three-phase line if it is not balanced, for example when controlled by an inverter or thyristor. Since there is no integration function, it is not possible to measure total energy consumed ( Wh) . Specifications: Measurement line Single-phase, Three-phase ( should be balanced and no distortion) Measurement items Voltage, Current, Voltage/ current peak, Active/ reactive/ apparent power, Power factor, Phase angle, Reactivity, Frequency, Voltage/ current harmonic levels Voltage ranges 30 - 1kHz 150.0 V to 600 V, 3 ranges Basic accuracy: ± 1.0 % rdg. ± 3 dgt. ( at 45 - 66 Hz, True RMS) Current ranges 45 - 1kHz 20.00 A to 1000 A, 3 ranges Basic accuracy: ± 1.3 % rdg. ± 3 dgt. ( at 45 - 66 Hz, True RMS) Power ranges 80 - 600 V 1 - 1000 A [ Single phase] 3.000 kW to 600.0 kW Basic accuracy: ± 2.3 % rdg. ± 5 dgt. ( at 50/ 60 Hz, Power factor = 1) [ Balanced three phase] 6.000 kW to 1200 kW Basic accuracy: ± 3.0 % rdg. ± 10 dgt. ( at 50/ 60 Hz, Power factor = 1) Harmonic levels Voltage/ current harmonic levels up to 20th, Content factor, Total harmonic distortion ratio Other function [ Phase angle] Forward 90.0° to 0 to delay 90.0° [ Power factor] Forward 0 to 1.000 to delay 0 [ Frequency] 30.0 Hz to 1000 Hz Waveform peak, Phase detection, Max. / Min. value record, Data hold, Auto-power off, RS-232C output ( Options are discontinued, so cannot use RS-232C) Display LCD, Max. 6000 digits, Display refresh rate: 1 time/ s ( Normal) 1 time/ 3sec ( Slow) , 1 time/ 2sec ( Harmonic level) Power supply Stacked alkaline battery ( 6LR61, 6LF22) × 1, Continuous use: 25 hours Core jaw dia. Æ 55 mm ( 2.17 in) or 80 mm ( 3.15 in) × 20 mm ( 0.79 in) busbar Dimensions, mass 100 mm ( 3.94 in) W × 287 mm ( 11.3 in) H × 39 mm ( 1.54 in) D, 650 g ( 22.9 oz) Supplied accessories CARRYING CASE 9245 × 1, VOLTAGE CORD L9635-01 × 1, Hand strap × 1, Dry cell battery ( 6LF22) × 1, Instruction Manual × 1
Tampilkan Lebih Banyak