Detail HEAT INDEX WBGT METER ( LUTRON WBGT-2010SD)

FEATURES * Introduction : Data error no. 0.1% of total saved data max. Black globe temperature ( TG ) WBGT ( wet-bulb globe temperature ) was developed Memory Card SD memory card. 1 GB to 16 GB Range  0 to 80  as a monitoring basis at US military training camps Advanced * Set clock time ( Year/ Month/ Date, 32 to 176 . and became widespread for the use in workplaces and setting Hour/ Minute/ Second ) Resolution  0.1  sports situation It is suggested in the international * Set WBGT alarm value 0.1 standard ISO 7243, OSHA ( US Occupation Safety ) , * Decimal point of SD card setting Accuracy  0.6  Japan Society for Occupational Health and the SMA ( * Auto power OFF management @ 15 to 40  1.1 Sports Medicine Australia ) in establishing the * Set beep Sound ON/ OFF permissible heat exposure limits in health , sports or * Select the temperature unit to  or . Humidity other physical activities. * Set sampling time Range 5 % to 95 % R.H. * Measurement : WBGT value ( Indoor/ Outdoor Wet bulb * SD memory card Format Resolution 0.1 % R.H. globe temperature ) , Black globe temperature, Humidity, Data Hold Freeze the display reading. Accuracy g70% RH : Air temperature, Wet bulb temperature, Dew point Temp.. Memory Recall Maximum & Minimum value. ( 3% reading + 1% RH) . * Adjustable WBGT alarm setting, if the WBGT value over Sampling Time Approx. 1 second. < 70% RH : the alarm threshold, the buzzer will sound along with of Display 3% RH. the flashing Display. Data Output RS 232/ USB PC computer interface. * Using to control and monitor of physical activity in hot * Connect the optional RS232 cable Dew Point Temp. environment to limit the danger of heat related UPCB-02 will get the RS232 plug.  Range -25.3  to 48.9  injuries. * Connect the optional USB cable Resolution 0.1  * Globe temperature measurement use the Pt sensor, USB-01 will get the USB plug. Range -13.5 to 120.1 . high accuracy. Operating 0 to 50  . Resolution 0.1 . * Fast humidity measuring response time. Temperature Remark : * Dew Point Temp. value is calculated from the * Direct measurement of the radiation effect with a brass Operating Less than 85% R.H. Humidity/ Air Temp. measurement automatically. black ball in 75 mm dia. Humidity * The Dew Point Temp. accuracy is sum accuracy value * Sensor protecting mechanism. Power Supply * AAlkaline or heavy duty DC 1.5 V battery of Humidity & Air Temperature measurement.. * Real time SD memory card Datalogger, it Built-in Clock ( UM3, AA ) x 6 PCs, or equivalent. and Calendar, real time data recorder , sampling time set * ADC 9V adapter input. ( AC/ DC power Wet bulb Temp. from 1 second to 3600 seconds. adapter is optional ) .  Range -21.6  to 50.0  * Manual datalogger is available ( set the sampling Power Current Normal operation ( w/ o SD card save Resolution 0.1  time to 0 ) , during execute the manual datalogger data and LCD Backlight is OFF) : Range -6.9 to 122.0 . function, it can set the different position ( location ) No. Approx. DC 5 mA. Resolution 0.1 . ( position 1 to position 99 ) . When SD card save the data but and Remark : * Wet bulb display value is calculated from the * Innovation and easy operation, computer is not LCD Backlight is OFF) : Humidity/ Air Temp. measurement automatically. need to setup extra software, after execute Approx. DC 25 mA. * The Dew Point accuracy is sum accuracy value of datalogger, just take away the SD card from the * AIf LCD backlight on, the power Humidity & Air temperature measurement.. meter and plug in the SD card into the computer, consumption will increase approx. it can down load the all the measured value with 11 mA. Recommendations to heat exposure level the time information ( year/ month/ date/ Weight 489 g/ 1.08 LB. for working and physical activity. hour/ minute/ second ) to the Excel directly, then Dimension Meter 177 x 68 x 45 mm ( Permissible heat exposure threshold limit ) user can make the further data or graphic Black brass ( 7.0 x 2.7x 1.9 inch) analysis by themselves. ball Round, 75 mm dia Work/ rest regimen Light Moderate Heavy * SD card capacity : 1 GB to 16 GB. Standard * Instruction manual............................1 PC ( Each hour ) * LCD with green light backlight, easy reading. Accessories * Black brass ball ( with sensor ) ....... 1 PC * Can default auto power off or manual power off. Included * Soft carrying case, CA-05B................1 PC Continuous work 30  26.7  25  * Data hold, record max. and min. reading. Optional * SD Card ( 2 GB ) ( 86 ) ( 80 ) ( 77 ) * Microcomputer circuit, high accuracy. Accessories * AC to DC 9V adapter. * Power by UM3/ AA ( 1.5 V ) x 6 batteries or DC 9V * USB cable, USB-01. 75% work, 25% rest 30.6  28  25.9  adapter. * RS232 cable, UPCB-02. ( 87 ) ( 82 ) ( 78 ) * RS232/ USB PC COMPUTER interface.
temperature sensor
Tampilkan Lebih Banyak