Back to Top

Hi, Guest!

  LOKASI :  Kota Cimahi

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • 4-20 mA Control/ Alarm/ Indicator ( LUTRON CT-2012)

4-20 mA Control/ Alarm/ Indicator ( LUTRON CT-2012)

Update Terakhir
:
15 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
62 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail 4-20 MA Control/ Alarm/ Indicator ( LUTRON CT-2012)

FEATURES * Input : 4-20 mA DC, linear. Relay Output Number 2 relays * User can default the desired display value between Function Relay 1 : -1999 to 9999 ( decimal point can be selected to DP1, High/ Low control relay. DP2, DP3 ) and all the preset data will be saved into Relay 2 : the memory circuit permanently. High/ Low alarm relay. * According the 4 to 20 mA input signal, user can preset Max load 0.5 ACA/ 250 ACV the desire display value between -1999 to 9999 ( decimal 0.5 DCA/ 24 DCV point can select to DP1, DP2, DP3 ) . Until set the display * Do not apply the relay value, all the data will save into the memory circuit contact load current permanently > 0.5 A, other wise the * When CT-2012 cooperate LUTRON' s 4 to 20 mA relay may be damaged transmitters ( or any other transmitters if it build 4 to permanently without 20 mA output signal ) , whole system will become the warranty. high performance Controller/ Alarm/ Indicator for * Decimal point adjustment : following measuring functions : Humidity, Light, pH, DP1, DP2, DP3 Dissolved Oxygen, Conductivity, Vibration, Pressure, Main * Low limit of range adjustment Sound, Temperature, RPM, Hz, Load cell ( Weight, Internal 4 mA = X X X X, min. value is -1999 Force ) , Potential ( Angle, Level ) . ACV, ACA, DCV, Function * High limit of range adjustment DCA, WATT.... Selection 20 mA = X X X X, max. value is 9999 * Easy to adjust the function factors by push button * Alarm function adjustment : on the front panel. High Alarm or Low alarm. * Control output : 2 points ( COM, NO ) . * Control function adjustment * Alarm output : 2 points ( COM, NO ) . High control or Low control. * Control Relay will make action when the reading value * Deviation of Alarm reach to control value. * Deviation of Control * Hysteresis value setting for control and alarm function. * Filter value of display reading * Large red LED display, high brightness and easy to read. * Offset adjustment. * Microprocessor circuit ensures high accuracy and * Gain adjustment. provides special functions and features. * RS232 output unit code setting * DC 12V power supply output. Default of internal function : * RS232/ USB computer interface. Without advice previously, the function * Power : 90 ACV - 264 ACV, 50/ 60 Hz. of CT-2012 will preset : * Standard 96 X 48 mm DIN case. * 4 mA = 0, 20 mA = 9999. * Optional data acquisition software.
Tampilkan Lebih Banyak